VDA 355 Module Low Temperature Voltage Window Explained
Short answer: Below 0 °C, the minimum cell voltage of a 2P6S VDA 355 NMC module drops from 16.5 V to 13.2 V, widening the lower end of the voltage window. For an 18-module series string, that shifts the minimum string voltage from 297 V down to roughly 238 V. The inverter or motor controller minimum input voltage determines whether that matters.
Engineers sizing a battery pack for a vehicle or industrial system in a cold climate often discover that the voltage window in the datasheet is not a single pair of numbers. It is temperature-dependent, and the lower boundary moves in ways that affect inverter compatibility and control logic, even before any discussion of usable capacity or power capability.
This article works through the 2P6S VDA 355 NMC module as a concrete example, shows the arithmetic for a realistic series string, and explains what the numbers do and do not tell you.
What the 2P6S VDA 355 Module Looks Like
A VDA 355 module is a standardised prismatic battery module measuring approximately 355 x 151 x 108 mm, designed so that modules from different cell suppliers share a common mechanical envelope, cooling interface and busbar layout. The format and its standard configurations are defined through the German automotive industry association (VDA).
The 2P6S configuration means two cells in parallel per group, six groups in series. The catalogue figures for this NMC module are:
| Parameter | Value |
|---|---|
| Nominal voltage | 22.02 V |
| Nominal energy | 2.55 kWh |
| Mass | 12.2 kg |
| Voltage window, 0 to 55 °C | 16.5 to 26.1 V |
| Voltage window, -30 to below 0 °C | 13.2 to 26.1 V |
The maximum voltage, 26.1 V, does not change with temperature. Only the minimum changes.
Why the Minimum Voltage Shifts Below 0 °C
In NMC chemistry, cell voltage under load drops more steeply at low temperatures because ionic conductivity in the electrolyte decreases. A cell that would reach its lower cut-off voltage at a certain state of charge under warm conditions will reach a lower terminal voltage at the same state of charge under a cold load, particularly during high-rate discharge.
The datasheet accounts for this by specifying a wider voltage window at sub-zero temperatures: the lower boundary moves from 16.5 V at 0 °C and above to 13.2 V below 0 °C. This is not an invitation to discharge the module deeper in absolute energy terms. It is a statement about the voltage the module's terminals may present under those conditions.
For a detailed explanation of how cell chemistry affects the operating envelope, the comparison of NMC chemistry in a VDA 355 module gives useful context.
The IEC standard IEC 62619 (available via iec.ch) sets safety requirements for lithium cells and batteries used in stationary and mobile applications, including requirements for testing across the operating temperature range. The voltage window in a datasheet must be understood within the bounds set by that standard for the specific cell.
Calculating a Series String: 18 Modules
A common pack architecture for a traction or industrial application places multiple modules in series to reach a target bus voltage. Using 18 of these 2P6S modules in series:
Nominal string voltage: 18 x 22.02 V = 396.36 V, rounded to approximately 396 V.
Maximum string voltage: 18 x 26.1 V = 469.8 V, approximately 470 V.
Minimum string voltage, 0 to 55 °C: 18 x 16.5 V = 297 V.
Minimum string voltage, below 0 °C: 18 x 13.2 V = 237.6 V, approximately 238 V.
The full picture in table form:
| Condition | Minimum string voltage | Maximum string voltage |
|---|---|---|
| 0 to 55 °C | 297 V | 470 V |
| -30 to below 0 °C | 238 V | 470 V |
The arithmetic is straightforward, but the implications for system design are not trivial.
What This Means for the Inverter or Motor Controller
Every inverter and motor controller has a minimum DC input voltage below which it will not operate, or will shut down to protect itself. If the battery string voltage can reach 238 V in cold conditions, the inverter must tolerate that voltage without tripping.
If the inverter minimum input voltage is, for example, 250 V, then a string of 18 modules at very low state of charge in sub-zero temperatures will cause an undervoltage fault before the battery management system has reached its own cut-off threshold. The pack design must address this either by raising the string count, by setting a higher minimum state of charge in the BMS, or by choosing an inverter with a lower minimum input threshold.
The series and parallel configuration guide for VDA 355 packs covers string sizing in more detail.
What the Voltage Window Does Not Tell You
It is important to be clear about what this specification does not cover:
- Available capacity in the cold: The voltage window says nothing about how much energy is accessible below 0 °C. Usable capacity at low temperatures depends on the cell's discharge curves at different temperatures and C-rates, which are in the datasheet. Do not assume that because the voltage window is wider, more energy is available.
- Power capability: Peak current and continuous current limits at low temperature are separate datasheet parameters. A wider voltage window does not imply higher or lower power capability.
- Degradation over cycles: Cold-weather operation affects long-term cycle life, but that is a cell-level and usage-pattern question. No figures for cold-climate degradation should be inferred from voltage window data alone.
The datasheet is the governing document for all of these parameters.
Practical Implications for Pack Architects
For engineers specifying a pack for use in climates below 0 °C, the following points follow directly from the numbers above:
- Use the sub-zero minimum voltage (238 V for 18 modules) as the worst-case lower boundary in your inverter compatibility check, not the ambient-temperature figure of 297 V.
- Set BMS undervoltage protection thresholds with enough margin above the inverter minimum input voltage to account for voltage sag under load.
- If the system uses active thermal management to keep modules above 0 °C before and during discharge, the ambient-temperature window (297 to 470 V) applies. Document the assumption.
- Verify all operating limits against the specific module datasheet. The figures in this article are catalogue values for the 2P6S NMC VDA 355 module; variants differ.
For broader context on how the VDA 355 format is used outside passenger cars, including in systems where low-temperature operation is a primary design constraint, see VDA 355 module applications in industrial and marine environments.
The EU Battery Regulation 2023/1542 (published at EUR-Lex, europa.eu) introduces performance and durability requirements, including capacity retention at low temperatures, for batteries placed on the EU market. Pack designers should be aware of these requirements when selecting modules and writing system documentation.
Next Steps
Review the full module specifications and datasheet parameters for the 2P6S and other NMC VDA 355 configurations in the Avantis Energy module range, or contact Avantis Energy with a technical question about string sizing, inverter compatibility or cold-climate operation.
Frequently asked questions
What is the voltage window of a 2P6S VDA 355 NMC module at low temperature?
Below 0 °C, the voltage window is 13.2 to 26.1 V. Between 0 and 55 °C, the minimum rises to 16.5 V. The maximum of 26.1 V is the same in both ranges. All figures are catalogue values; the datasheet for the specific module governs.
Why does the minimum voltage of a VDA 355 module drop below 0 °C?
At sub-zero temperatures, reduced ionic conductivity in the NMC electrolyte causes a steeper voltage drop under load. The cell can reach a lower terminal voltage at the same state of charge compared with warm conditions, so the specified lower boundary of the voltage window moves down to reflect this behaviour.
How do I calculate the voltage window for a series string of VDA 355 modules?
Multiply the per-module minimum and maximum voltages by the number of modules in series. For 18 modules: minimum 18 x 16.5 V = 297 V at 0 to 55 °C, or 18 x 13.2 V = 238 V below 0 °C; maximum 18 x 26.1 V = 470 V in both cases.
Does a wider cold-weather voltage window mean more energy is available in the cold?
No. The voltage window defines the terminal voltage range the module may present; it does not describe available capacity or power capability at low temperatures. Those parameters are stated separately in the cell and module datasheet and must be used for energy and power sizing.
What voltage must my inverter support when using VDA 355 modules in cold climates?
The inverter minimum DC input voltage must be at or below the minimum string voltage at the lowest operating temperature. For 18 modules below 0 °C, that is approximately 238 V. If the inverter minimum exceeds this figure, undervoltage faults will occur before the BMS cut-off, and the system design must be adjusted accordingly.