VDA 355 Module Energy Density: Wh/kg Compared
Short answer: The three VDA 355 configurations deliver 209 to 214 Wh/kg at module level. The 1P4S reaches 214 Wh/kg at 11.85 kg; both the 2P6S and 3P4S reach 209 Wh/kg at 12.2 kg. All share the same 355 x 151 x 108 mm envelope, giving an indicative volumetric figure of roughly 440 to 446 Wh per litre of external volume.
Energy density at module level sets the floor for what a finished pack can achieve. Every kilogram of enclosure, cooling plate and cabling added during pack assembly reduces the system-level figure below the module catalogue value. For engineers sizing a pack, the starting point is therefore the module specifications: gravimetric energy density in Wh/kg and, where envelope space is constrained, volumetric energy density in Wh per litre.
This article works through those figures for the three VDA 355 configurations currently in the VDA 355 module catalogue, shows the arithmetic behind them and demonstrates how the numbers translate into a realistic pack estimate.
The three VDA 355 configurations: catalogue data
All three modules share the same external dimensions: 355 x 151 x 108 mm. The cell count and string arrangement differ, which determines voltage and total energy. All three use NMC chemistry.
| Configuration | Nominal energy | Mass | Catalogue Wh/kg | Calculated Wh/kg |
|---|---|---|---|---|
| 1P4S | 2.59 kWh | 11.85 kg | 214 Wh/kg | 218 Wh/kg |
| 2P6S | 2.55 kWh | 12.2 kg | 209 Wh/kg | 209 Wh/kg |
| 3P4S | 2.59 kWh | 12.2 kg | 209 Wh/kg | 212 Wh/kg |
The calculated column (energy divided by mass) shows minor deviations from the catalogue value for the 1P4S and 3P4S. These small differences reflect rounding in the published energy and mass figures, or differences in measurement method; no specific cause should be assumed. The catalogue Wh/kg value is the reference figure to use in specifications.
Volumetric energy density: an indicative figure
The external volume of a 355 x 151 x 108 mm module is:
0.355 m x 0.151 m x 0.108 m = 0.005786 m³, or approximately 5.79 litres.
Applying that to the three configurations:
- 1P4S: 2,590 Wh / 5.79 L = approximately 447 Wh/L
- 2P6S: 2,550 Wh / 5.79 L = approximately 440 Wh/L
- 3P4S: 2,590 Wh / 5.79 L = approximately 447 Wh/L
The range across all three is roughly 440 to 447 Wh per litre. This figure is based on the outer envelope, not on the net internal volume available to cells. It is useful as a first-pass comparison between module formats but should not be used in detailed thermal or structural calculations, where actual geometry from the mechanical drawing applies. For a fuller explanation of module dimensions, see VDA 355 module dimensions and specifications.
Why the configurations cluster so closely
The 1P4S, 2P6S and 3P4S occupy the same box. The mass difference between 11.85 kg and 12.2 kg is small (less than 3 %), and the energy difference between 2.55 kWh and 2.59 kWh is also small (less than 2 %). As a result, all three sit within a narrow band: 209 to 214 Wh/kg at module level.
The choice between them is therefore driven by voltage architecture rather than by a material difference in energy density. A pack designer selects the configuration that places the string voltage in the target range for the inverter or motor controller, then calculates module count from the required total energy. The pack design guide for series and parallel arrangements covers that calculation in detail.
Worked example: 70 kWh pack using 1P4S modules
Target: approximately 70 kWh at module level.
Module energy: 2.59 kWh per module.
Module count: 70 kWh / 2.59 kWh = 27.0, so 27 modules.
Total module energy: 27 x 2.59 kWh = 69.93 kWh, approximately 70 kWh.
Total module mass: 27 x 11.85 kg = 319.95 kg, approximately 320 kg.
That 320 kg represents the modules only. A complete pack adds the mass of the enclosure, structural frame, cooling system (plates, pipes, fluid), busbars, wiring harness, connectors and any BMS hardware. Depending on pack architecture, the non-module mass for a 27-module pack typically adds a significant fraction on top; the exact figure depends on the specific design and must be derived from the actual component specifications. System-level gravimetric energy density will therefore be lower than the 214 Wh/kg module figure. The IEA and research institutions such as Fraunhofer have documented the relationship between cell-level, module-level and pack-level energy density in EV battery systems; at pack level, a reduction of 20 to 30 % relative to module-level Wh/kg is a commonly cited range, though actual values depend on the specific design.
Comparing module formats: VDA 355 versus MEB 590
Engineers evaluating module-level energy density for a new pack design may also consider the MEB 590 format. The MEB 590 module is physically larger (approximately 590 mm long) and carries more cells, which changes the balance between module-level and pack-level efficiency. A direct format comparison is in the article VDA 355 vs MEB 590: which battery module format fits your pack?.
For the VDA 355 format, the compact envelope is a practical advantage in applications where the installation space is segmented or where the module mass per unit must stay manageable during assembly. The standardised format also means that module-level specifications from different suppliers are mechanically comparable, as explained in the background of the VDA 355 format.
For transport compliance, all lithium battery modules shipped internationally must comply with UN 38.3, the UN transport testing standard administered by UNECE (unece.org). Module-level certification under UN 38.3 covers the module as a finished article and is separate from cell-level certification.
Next step
To review the full module specifications for all three VDA 355 configurations, visit VDA and MEB battery modules from Avantis Energy. For technical questions on pack sizing or module selection, contact Avantis Energy directly.
Frequently asked questions
What is the gravimetric energy density of a VDA 355 module in Wh/kg?
The three VDA 355 configurations deliver 209 to 214 Wh/kg at module level according to the catalogue. The 1P4S achieves 214 Wh/kg at 11.85 kg; the 2P6S and 3P4S each achieve 209 Wh/kg at 12.2 kg. The catalogue figure is the reference value to use in specifications.
How is the volumetric energy density of a VDA 355 module calculated?
Divide the nominal energy in Wh by the external volume. The 355 x 151 x 108 mm envelope is approximately 5.79 litres. The three configurations therefore yield roughly 440 to 447 Wh per litre of outer volume. This is an indicative figure based on external dimensions, not net cell volume.
How much does a VDA 355 module weigh?
The 1P4S configuration weighs 11.85 kg. The 2P6S and 3P4S configurations each weigh 12.2 kg. All three share the same 355 x 151 x 108 mm external envelope. The datasheet for the specific configuration is the authoritative source.
How many VDA 355 modules are needed for a 70 kWh pack?
Using the 1P4S at 2.59 kWh per module: 70 kWh / 2.59 kWh = 27 modules, giving 69.93 kWh and a combined module mass of 27 x 11.85 kg = 319.95 kg, approximately 320 kg. Pack enclosure, cooling and wiring add further mass on top of that figure.
Does the choice of VDA 355 configuration significantly affect energy density?
No. All three configurations sit within a narrow band of 209 to 214 Wh/kg and 440 to 447 Wh/L. The selection between 1P4S, 2P6S and 3P4S is driven primarily by the target string voltage for the inverter or drivetrain, not by a material difference in energy density.