VDA 355 Module 1P4S & 2P6S: What the Notation Means

Short answer: In battery module notation, P is the number of cells connected in parallel and S is the number connected in series. A 1P4S NMC module has 4 cells in series, giving roughly 14.64 V nominal and 2.59 kWh at 177 Ah. A 2P6S module has 6 cells in series and 2 in parallel, giving roughly 22.02 V and 2.55 kWh at 116 Ah.

Battery module datasheets express cell arrangement with two numbers: a P value and an S value. Once you understand what each controls, you can derive nominal voltage, capacity and energy directly from the catalogue figures without ambiguity.

What P and S mean

The notation follows a consistent convention across the industry. The S value (series) sets the module voltage. The P value (parallel) sets the module capacity.

  • S (series): cells are connected positive-to-negative in a chain. Each cell voltage adds to the next. Four cells in series produce four times a single-cell voltage.
  • P (parallel): cells are connected positive-to-positive and negative-to-negative. Each cell contributes its full capacity. Two cells in parallel produce twice the capacity of one cell, at the same voltage.

Energy then follows from the product of the two:

Energy (kWh) = Nominal voltage (V) × Capacity (Ah) ÷ 1,000

That relationship holds regardless of chemistry or format. The IEC standard IEC 62619 for secondary lithium cells and batteries uses the same definitions.

Worked example 1: the 1P4S module

Catalogue figures for the 1P4S NMC module:

  • Nominal voltage: 14.64 V
  • Capacity: 177 Ah

Step 1: derive the per-cell voltage. The module has 1P4S, so 4 cells in series and 1 in parallel.

14.64 V ÷ 4 cells = 3.66 V per cell (nominal)

That is a typical nominal figure for an NMC prismatic cell.

Step 2: derive the per-cell capacity. With P = 1, the module capacity equals one cell's capacity.

177 Ah ÷ 1 = 177 Ah per cell

Step 3: calculate module energy.

14.64 V × 177 Ah ÷ 1,000 = ≈ 2.59 kWh

Worked example 2: the 2P6S module

Catalogue figures for the 2P6S NMC module:

  • Nominal voltage: 22.02 V
  • Capacity: 116 Ah

Step 1: derive the per-cell voltage. The module has 2P6S, so 6 cells in series.

22.02 V ÷ 6 cells = 3.67 V per cell (nominal)

Consistent with the same NMC cell family used in the 1P4S.

Step 2: derive the per-cell capacity. With P = 2, the module capacity is shared across 2 parallel cells.

116 Ah ÷ 2 = 58 Ah per cell

Step 3: calculate module energy.

22.02 V × 116 Ah ÷ 1,000 = ≈ 2.55 kWh

The two modules carry almost identical energy despite having different voltages and capacities, because a higher cell count in series raises voltage while a lower per-cell capacity keeps total energy similar.

Side-by-side comparison

Parameter 1P4S NMC 2P6S NMC
Cell arrangement 1 parallel, 4 series 2 parallel, 6 series
Nominal voltage 14.64 V 22.02 V
Module capacity 177 Ah 116 Ah
Per-cell voltage (derived) 3.66 V 3.67 V
Per-cell capacity (derived) 177 Ah 58 Ah
Module energy (calculated) ≈ 2.59 kWh ≈ 2.55 kWh
Chemistry NMC NMC

Why the distinction between P and S matters for pack design

When you assemble modules into a pack, the same logic scales up. Connecting VDA 355 modules in series multiplies the voltage; connecting them in parallel multiplies the capacity. A pack designer choosing between a 1P4S and a 2P6S module is therefore choosing a different bus voltage at module level, which propagates into the pack string voltage and the inverter or motor controller interface.

For a detailed look at how these modules are combined into full pack strings, the article on VDA 355 battery pack design: series and parallel configuration covers string architecture and voltage arithmetic at pack level.

The advantages of the VDA 355 format include precisely this mechanical and electrical standardisation: the same 355 mm envelope accommodates different P/S arrangements, so a pack designer can switch between configurations without redesigning the mechanical structure.

Reading the full datasheet

The calculations above use nominal voltage and rated capacity from the catalogue. Additional figures such as charge and discharge cut-off voltages, peak current ratings and temperature ranges are stated on the datasheet and govern actual operating limits. For a full explanation of each datasheet parameter and what it means for integration, see the VDA 355 module datasheet: key figures explained on this site. Where a figure is not listed in the catalogue entry, the datasheet is the authoritative source.

Frequently asked questions

What does 1P4S mean on a VDA 355 battery module?
1P4S means 1 cell in parallel and 4 cells in series. The S count determines nominal voltage: 4 cells at roughly 3.66 V each give 14.64 V. The P count of 1 means module capacity equals one cell's capacity, here 177 Ah, for approximately 2.59 kWh total energy.

What does 2P6S mean on a battery module?
2P6S means 2 cells in parallel and 6 cells in series. Six series cells at roughly 3.67 V each produce 22.02 V nominal. Two parallel cells share the 116 Ah module capacity, so each cell contributes 58 Ah. Total module energy is approximately 2.55 kWh.

How do you calculate the energy of a battery module from P and S notation?
Multiply nominal voltage by rated capacity in Ah, then divide by 1,000. Nominal voltage equals the per-cell voltage multiplied by S. Rated capacity equals the per-cell capacity multiplied by P. The result is module energy in kWh. This holds for any P/S arrangement.

Does P/S notation change with battery chemistry?
No. The notation is chemistry-neutral and describes only how cells are connected. The per-cell voltage will differ between chemistries, which is why the derived per-cell voltage in a worked example indicates the chemistry family, but the arithmetic method is identical regardless of chemistry.

Where can I find the full electrical specifications for each VDA 355 module configuration?
The datasheet for each module configuration carries nominal voltage, rated capacity, charge and discharge voltage limits, and current ratings. Catalogue figures give the basis for the energy calculation; all operating limits are taken from the datasheet, which is the authoritative reference for integration work.

Next steps

For specifications on the full range of NMC module configurations in the VDA 355 and MEB 590 formats, visit VDA and MEB battery modules from Avantis Energy. Technical questions on cell arrangement, pack voltage or integration requirements can be directed to the Avantis Energy engineering team.

Next step · both links open avantisenergy.eu

Building a pack on VDA 355?

Avantis Energy supplies prismatic LFP and NMC cells and complete VDA-format modules, so you integrate a proven module instead of validating your own. The catalogue lists 24 module types and 20 cell types.

Request a quote from Avantis EnergyTell us configuration, voltage and quantity. No account needed.
View the VDA module range